Customer rang to say that there was a small drip coming from the right hand side underneath the boiler.
Location:
- Wynyard Close, Sale M33 3JT
Property Type:
- Semi Detached
Boiler Type:
- Viesman Vitodens 100-W 35Kw Combi Boiler
Job Report
Upon inspection we found that the auto air vent was leaking contaminated water from the central heating system.
We replaced the auto air vent and carried out a full system power flush to clean all the central heating pipework, boiler and radiators and the system was dosed with a premium anti corrosion inhibitor.
We recommended fitting a magnetic filter to protect the boiler and system in the future.
A visual inspection and check of the boiler repair was carried out, followed by a gas safety check and a flue gas analysis.
Related Repairs
- Ideal Logic Repaired with Loud Noises When Running on Demand
- Repair on Worcester CDI with Heat but No Hot Water
- Boiler Ignition Problems & Noises in Sale
- Ideal Logic Boiler Working Intermittently in Sale
- Boiler Repair Call Out for Loud Noise in Ideal Logic