Customers Worcester Bosch boiler was not fining up heating or hot water demands.
Location:
- Oak Road, Sale M33 2FD
Property Type:
- Mid Terrace Mews
Boiler Type:
- Worcester Bosch CDI

Job Report
Gas Type: Natural Gas
Problem: Ignition lockout
Symptoms:
- Boiler not firing up
Diagnosis:
Repairs Performed:
- Replaced ignition electrodes
Notes:
- Boiler is now operating normally and should continue to do so for the years to come.
- Recommended to the customer to have their boiler serviced annually to prevent future problems.
Additional Information:
We replaced the ignition electrodes as part of the boiler repair and then carried out a full service on the boiler. Burner was contaminated with debris and required flushing out. Condensate trap was contaminated with aluminium oxide and required cleaning. The gas gas was calibrated as part of the service.
A visual inspection and check of the boiler was carried out, followed by a gas safety check and a flue gas analysis.
Problems with your Worcester boiler? Manchester Plumbing and Heating (Sale) provide fast and Efficient Worcester Bosch Boiler Repairs in Sale Manchester! Our experienced team is here to provide fast and efficient repairs, ensuring your home remains warm and cosy.
Related Repairs
- Worcester Bosch Flow Temperature Fluctuating
- Worcester Bosch Boiler Blocked Condensate Sump Repaired
- Worcester Bosch Boiler RHS Manifold Replaced
- Ignition Error Repaired on Worcester Bosch